Measuring pH, mass and volume, and choosing an indicator
- 3 things to know
- Components 01 and 03
Overview
Recall questions on the resolution of a burette and a balance, making up a standard solution, and matching an indicator to a titration.
What you need to know
Answer each one before you reveal it.
What mass of sodium carbonate (Mᵣ 106.0) makes 250 cm³ of 0.100 mol dm⁻³ solution, what is the concentration when 25.0 cm³ of it is diluted to 250 cm³, and why can no indicator suit a weak acid with a weak base?
25.0 cm³ of 0.100 mol dm⁻³ solution is diluted to 250 cm³. What is the new concentration?
Questions from this subtopic
Each one with the model answer underneath.
- 1
Why is a water bath used in preference to a naked flame for warming a volatile organic liquid, and when would a sand bath or electric heater be used instead?
Model answer
It supplies gentle, evenly distributed heat below 100 °C and removes the ignition source, so flammable vapour cannot catch fire; a sand bath or electric heater is used instead when the mixture must be heated above 100 °C.
- 2
Name three ways of measuring pH in the laboratory and state which gives the most precise value.
Model answer
pH can be measured with indicator paper and a colour chart, with a pH meter, or with a pH probe on a data logger; the meter or probe is the most precise because it reads to about 0.1 of a pH unit, whereas the paper gives only the nearest whole number and the colour is judged by eye.
- 3
Why must a pH meter be calibrated before use?
Model answer
The electrode response drifts with time and temperature, so it is set against buffer solutions of known pH to give correct readings.
- 4
Why must any air bubble be removed from the jet of a burette before the first reading is taken?
Model answer
If the bubble is expelled during the titration, its volume is recorded as solution delivered, so the titre comes out too large.
- 5
A thermometer has 1 °C divisions and a balance displays to 0.01 g. What is the uncertainty in a single reading from each?
Model answer
Each is uncertain by half the smallest division, so the thermometer reading is ±0.5 °C and the balance reading is ±0.005 g.
- 6
What mass of anhydrous sodium carbonate is needed to make 250 cm³ of a 0.100 mol dm⁻³ standard solution, given Mᵣ = 106.0?
Model answer
The amount required is 0.250 dm³ × 0.100 mol dm⁻³ = 0.0250 mol, so the mass is 0.0250 × 106.0 = 2.65 g.
Other ways to work this
The same content, four other ways.
What is inside Levo
Six ways to work the same material.
Every question in Development of Practical Skills in Chemistry, on a schedule.
Attempt a question from memory, write the correct version, then attempt it again. Levo records the jump between your first attempt and your last, and brings each question back on the day you are due to forget it.
Or £46 a year, about £3.83 a month. Cancel anytime.